Anisotropic magnetoresistive sensor based on manganite oxide targeting biomedical application
Overview & Synopsis
This work presents the design, fabrication, characterization and ultimately the optimization of single layer magnetic field sensors based on the anisotropic magnetoresistance (AMR) effect present in La2/3Sr1/3MnO3 (LSMO) thin films. The magnetic and electrical properties of this manganite oxide are linked through the double exchange mechanism. Thanks to the very low intrinsic noise of the material in the low frequency region, it presents itself as a competitive candidate for sensing magnetic fields targeting biomedical applications, such as the one envisioned by the European project ByAxon. The sensor must be of small size, operate at body temperature and achieve detectivity values in the range of hundreds of pT Hz-1/2 below 1 kHz. The fabrication of this AMR sensor is quite simple when comparing to giant magnetoresistance and tunneling magnetoresistance devices, and its operation is based on a step-induced uniaxial magnetic anisotropy explained using the Stoner-Wohlfarth model. This is obtained by growing epitaxial films with Pulsed Laser Deposition (PLD) technique on top of vicinal SrTiO3 (STO) substrates. To have the dominant contribution for the total electrical noise of the whole system coming from the sample itself, a low noise amplifier adapted to sample characteristics was built. Two Wheatstone bridge structures were etched in the LSMO thin films, presenting different current density directions regarding the easy magnetization axis. One structure is ruled by the planar Hall effect and presents a linear operation around zero magnetic field, whereas the second depends on standard AMR terms and requires a static bias field for correct operation. The operation mode of both structures was validated with Magneto-optical Kerr Effect imaging and fitting a numerical physical model to experimental data, which also allows the extraction of physical parameters. Several studies were performed in order to achieve lower detectivity values, thus improved performance: effect of thin film thickness, vicinal angle of the STO substrate, PLD deposition temperature and lithography masks designs variations. The sample with best low frequency performance presents 1.4 nT Hz-1/2 detectivity at 1 Hz and 240 pT Hz-1/2 at 1 kHz, while working at 310 K. Some samples were mounted on printed circuit boards with wire bonding, and covered with polydimethylsiloxane, a biocompatible polymer. Characterization with alternating and inhomogeneous magnetic fields was performed, and different gradiometer arrangements were validated. No live records of magnetic fields emitted by spontaneous activity of incubated neuronal cells were obtained by the time this thesis was concluded, however this work presents a real application of a spintronics device based on a functional oxide and pushes further development in this growing area of new technologies.
hal.science)
← / → for pages • + / - for zoom • 0 to fit width
Powered by Mozilla PDF.js v3.11
Document Information
| Document Title | Anisotropic magnetoresistive sensor based on manganite oxide targeting biomedical application |
|---|---|
| Author / Organization | Luiz Guilherme Enger |
| Subject & Discipline | Multidisciplinary Academic Open Research |
| Categories | Science & Mathematics |
| Publication Year | 2021 |
| License / Rights | Open Access / Creative Commons |
| Resource Verification | Listed PDF (Verification Pending) |
| Original Host Website |
HAL Open Science
(hal.science)
|
| File Format | application/pdf (Portable Document Format) |
| Language | EN |
| Catalog ID | DOC-232394 |
| Original Source Link | Visit Source Page on hal.science » |