Ensembles of nanoelectrodes as electrochemical and electrochemiluminescence sensing platforms for molecular diagnostics
Overview & Synopsis
Nanoelectrode ensembles (NEES) are prepared, functionalized and tested to prepare enzymatic and affinity sensors suitable for advanced molecular diagnostics purposes, namely the development of a miniaturized glucose biosensor and the preparation of novel electrochemical and electrochemiluminescence immunosensors for celiac disease diagnostics.For the first goal, a second generation enzymatic microbiosensor was developed exploiting the properties of NEEs prepared by electroless gold deposition in track-etched polycarbonate (PC) membrane. The micro-NEE glucose biosensor (overall radius of 400 μm) was obtained by immobilizing glucose oxidase (GOx) on the nonconductive PC component of the NEE, while the Au nanoelectrodes were used exclusively as transducers. The (Ferrocenylmethyl)trimethylammonium cation (FA+) was used as the redox mediator. The proposed biosensor showed outstanding analytical performances with a detection limit of 36 μM for glucose.The second goal concerns celiac disease (CD) diagnostics. CD is an auto-immune disorder which reflects in abnormally high blood levels of the anti-tissue transglutaminase (anti-tTG) antibody, suitable as biomarker for CD diagnosis. Existing diagnostic techniques lack the desired level of sensitivity and specificity so that a confirmatory biopsy test is required. To overcome this limit, in this work electrochemical (EC) and electrogenerated chemiluminescence (ECL) immunosensors are proposed and studied. The two kinds of sensor employ the same biorecognition platform, based on tTG as biorecognition layer and NEEs as electrochemical transducers. EC and ECL sensors differ by the label used to develop the detection signal. By exploiting the high affinity of PC for proteins, the capture agent tTG is at first immobilized on the PC of the NEEs obtaining a tTG-NEEs which captures anti-tTG. For EC detection, the label is a secondary Ab labeled with horseradish peroxidase, using hydroquinone as redox mediator to generate the detection signal. For ECL, the sensor, after capturing anti-tTG, is reacted with a biotinylated secondary antibody to bind streptavidinatede Ru(bpy)3+2 luminophore. Application of an oxidizing potential in tripropylamine (TPrA) solution generates an intense ECL suitable for the sensitive ECL detection of anti-TG. Note that TPrA acts as redox mediator and ECL co-reactant. Both EC and ECL sensors are applied to human serum samples, showing to be suitable to discriminate between healthy and celiac patients. A comparison between the two approaches indicates that the lowest detection limit, namely 0.5 ng mL-1 of anti-TG, is achieved with the ECL immunosensor.
hal.science)
← / → for pages • + / - for zoom • 0 to fit width
Powered by Mozilla PDF.js v3.11
Document Information
| Document Title | Ensembles of nanoelectrodes as electrochemical and electrochemiluminescence sensing platforms for molecular diagnostics |
|---|---|
| Author / Organization | Henok Baye Habtamu |
| Subject & Discipline | Multidisciplinary Academic Open Research |
| Categories | Science & Mathematics |
| Publication Year | 2015 |
| License / Rights | Open Access / Creative Commons |
| Resource Verification | Listed PDF (Verification Pending) |
| Original Host Website |
HAL Open Science
(hal.science)
|
| File Format | application/pdf (Portable Document Format) |
| Language | EN |
| Catalog ID | DOC-256211 |
| Original Source Link | Visit Source Page on hal.science » |